Several inputs (prometheus, influxdb_listener, etc..) and outputs (multiple influxdb, prometheus) of different types. prometheus inputs like below
[[inputs.prometheus]] interval = "300s" response_timeout = "30s" urls = [ "https://127.0.0.1:1111/metrics", "https://127.0.0.1:2222/metrics" ] namepass = [ "aaa", ] insecure_skip_verify = true
# Influx HTTP write listener [[inputs.influxdb_listener]] service_address = ":1111" read_timeout = "30s" write_timeout = "30s"
Telegraf 1.9.1 SLES 12 SP-3
Send signal to reload config:
pkill -SIGHUP telegraf
Telegraf crashes.
No panic.
2018-12-12T17:05:24Z D! [agent] Stopping service inputs 2018-12-12T17:05:24Z I! Stopped HTTP listener service on :1111 panic: runtime error: invalid memory address or nil pointer dereference [signal SIGSEGV: segmentation violation code=0x1 addr=0x0 pc=0x1305909] goroutine 97 [running]: github.com/influxdata/telegraf/plugins/inputs/prometheus.(*Prometheus).Stop(0xc0004a0360) /go/src/github.com/influxdata/telegraf/plugins/inputs/prometheus/prometheus.go:308 +0x29 github.com/influxdata/telegraf/agent.(*Agent).stopServiceInputs(0xc0000c0268) /go/src/github.com/influxdata/telegraf/agent/agent.go:636 +0xa1 github.com/influxdata/telegraf/agent.(*Agent).Run.func1(0xc00030dbd0, 0xc0000c0268, 0x250a860, 0xc000217480, 0xbefc6d9c3b5974f5, 0x251069f4, 0x3cd7260, 0xc0000c38c0) /go/src/github.com/influxdata/telegraf/agent/agent.go:75 +0x138 created by github.com/influxdata/telegraf/agent.(*Agent).Run /go/src/github.com/influxdata/telegraf/agent/agent.go:66 +0x3bb
[Include gist of relevant config, logs, etc.]
The text was updated successfully, but these errors were encountered:
Does https:/influxdata/telegraf/blob/1.9.1/plugins/inputs/prometheus/prometheus.go#L308 just need to be p.wg.Wait() instead of p.cancel()? Removing the cancel prevents the panic and allows telegraf to restart.
p.wg.Wait()
p.cancel()
Sorry, something went wrong.
Looks to me like we need to only call cancel if it is set. Right now it looks like it panics on shutdown unless you are using the k8s monitoring.
No branches or pull requests
Relevant telegraf.conf:
Several inputs (prometheus, influxdb_listener, etc..) and outputs (multiple influxdb, prometheus) of different types. prometheus inputs like below
System info:
Telegraf 1.9.1
SLES 12 SP-3
Steps to reproduce:
Send signal to reload config:
Telegraf crashes.
Expected behavior:
No panic.
Actual behavior:
Additional info: