Type Address Description(s) Verified Models
Device Interfaces? 0E NIM?  
System Interfaces? 1F SAM/RAM?  
User Interfaces 20 Master Thermostat STSTXBBUID01-B, Touch
User Interfaces? 21 Zone 1 UI/SS?  
User Interfaces? 22 Zone 2 UI/SS?  
User Interfaces? 23 Zone 3 UI/SS?  
User Interfaces? 24 Zone 4 UI/SS?  
User Interfaces? 25 Zone 5 UI/SS?  
User Interfaces? 26 Zone 6 UI/SS?  
User Interfaces? 27 Zone 7 UI/SS?  
User Interfaces? 28 Zone 8 UI/SS?  
Indoor Units 40 Furnace Bryant 355CAV 3 Stage Heat, Var Fan
Indoor Units 41    
Indoor Units 42 Fan Coil FE4A Series
Outdoor Units 50 Heat Pump Bryant 264AN 1 Stage HP
Outdoor Units 51 A/C?  
Other Devices 60 Damper Control?  
Other Devices 61 Damper Control?  
Other Devices 80  
Other Devices 92    
Special F1F1 Broadcast

Potential Equipment to Identify:

  • Damper Control Module (SYSTXCC4ZC01)
  • Smart Sensor (SYSTXCCSMS01)
  • NIM (SYSTXCCNIM01)
  • Control Zoning User Interface (SYSTXCCUIZ01)
  • Control User Interface (SYSTXCCUID01)
  • Touch Control with Wi-Fi
  • Touch Control
  • Infinity Remote Access Module
  • Service Tool