Notifications
You must be signed in to change notification settings - Fork 24
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Problem with alias variables #47
Comments
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
I've tried testing the expander and pump in the thermocycle library, each separately. I've connected them just to a sourceP and sinkP. I'm able to run the simulation, but a symbolic warning appears saying there are conflicting start and/or nominal values. It is able to run and solve if all the inputs are constant, but if I add a ramp it doesn't solve. Is there something I'm missing?
The text was updated successfully, but these errors were encountered: